Home / Rapid Test Reagents / Metronidazole Rapid Test Strip (Egg)

Metronidazole Rapid Test Strip (Egg)

Rapid Test Reagents · Yetta Bio

Metronidazole Rapid Test Strip (Egg) - rapid testReagents - Yetta Bio

Metronidazole Rapid Test Strip (Egg)

Rapid Test Reagents · Food Safety Rapid Testing

/📦 10T📝 Rapid Test · For livestock/poultry tissue, urine · Project-dependent

Rapid Test · For livestock/poultry tissue, urine · Project-dependent

← Rapid Test Reagents List
📦
Spec
10T
🏷️
SKU
/
🎯
LOD
10.0 μg/kg
GB 2761-2017
🔬
Method
Fluorescence Quantitative
🧪
Sample Type
livestock/poultry tissue, urine
Performance
Fluorescence Quantitative · For livestock/poultry tissue, urine · LOD10.0 μg/kg · Shelf Life: 12 months
🌡️
Storage
Store at 2–8°C
📅
Shelf Life
12 months
🔧Required Equipment & Consumables
🔬Equipment
(1) Pipette Set (20–200 μL, 100–1000 μL) , balance: (0.01 g) , vortex mixer, Sample Grinder, 500 mL Graduated Cylinder , sieve, Centrifuge (Min. Speed >4000r/ min) (Optional) , Constant Temp.Incubator, Fluorescence Reader
📦Consumables
(1) 50 mL Centrifuge Tube , (2) 2 mL Centrifuge Tube
📋Test Procedure Guide
1
Sample Prep
Take 300-500 g representative sample, Grind until ≥90% of particles pass through a 20-mesh sieve; Weigh 5.00±0.05 g sample into a 50 mL Centrifuge Tube, add 25 mL 50%ethanol-water extraction solution, 用vortex mixer 2600-2800 rpmSufficientlyShake3 min, Shake后Immediatelypour into2mL Centrifuge Tube; Handheld/PalmCentrifugeCentrifuge2 min; Collect supernatantSolution待Dilute; SamplediluentSufficientlyMix well; 取500 μLSamplediluent于2 mL Centrifuge Tube, add 100 μL待diluent, Mix well后Centrifuge1 minready for testing. (ObservesupernatantWhetherClear, if impurities are presentthenneedneed toappropriately extendCentrifugeTime) 注 2: Note: Due to highly uneven mycotoxin distribution in samples, proportionally increasing sample and extraction volumes improves repeatability. We offer three sample prep solutions for sample sizes of 5 g, 10 g, and 20 g.
2
Detection
Turn on the Thermostatic Incubator; ready to use once temperature reaches 37°C . Before the experiment, please carefully read this manual and the fluorescence reader operation instructions. Before use, allow the test card and the test solution to equilibrate to room temperature. Remove the test card from the original packaging bag, mark it, and use immediately. Using a pipette, vertically add 100 μL of the test solution into the sample well. Place on an incubator at 37°C and incubate for 8 minutes. Place the test card into the fluorescence reader to read the results.
Purchase Inquiry